HX Lighting Products

For underground mining, tunnelling and tunnel construction.

HX 320-48V-Single Output | Power Supply

Suitable for the HX 48v LED rope lights with single output. IP67 outdoor/hazardous environments.

Features

  •       Programmable Output Voltage 24v to 50v
  •       Constant Voltage mode LED power supply
  •       Supply Voltage: 90-305Vac, 380Vac for 2 Hours
  •       Surge Protected – Up to 10kV
  •       Customizable with Features (Energy Report, Input Voltage Monitoring)
  •       100,000Hour Life @ Tc=75°C
  •       5 Year Warranty @ Tc<=75°C
  •       Class II Model Available
  •       UL Class P, ENEC/CB/CCC SELV Output
  •       Safety according to EN 61347-1, 61347-2-3, 61347-2-13, 62384

Applications

Industrial: Conveyors, marine & submarine lighting, rail car lighting, catwalks, storage room lighting, accessways, wash down areas, service bays lighting, Crane machine houses & walkways, electrical rooms and bulk handling processing facilities.

Mining: Underground mine lighting for declines, shafts, drifts, crosscuts, longwall prep areas, electrical substations, jumbo box lighting, pump houses, cuddy and underground workshop lighting, crib rooms, accessways and escapeway lighting.

Tunnelling: Tunnel construction lighting, tunnel emergency lighting, sewerage & water utility tunnels, underpasses, train and pedestrian tunnels.

Specification

MODEL CV HX-BLD-320-48V-NNS-ADJ1000

OUTPUT

Output Voltage
Voltage Precision
Output Current
Output Power
Line Regulation

Adjustable 24V / 36V / 48V DC
±3% Vo
10A @24V / 8.9A @36V / 6.7A @48V
240W / 320W / 320W
1%

INPUT

Input Voltage Range
AC Current (Typ)

Inrush Current (Typ)

Frequency Range
PFC (Typ)
Full-loading Efficiency

90–305VAC, 380VAC for 2 hours
2.9A max @120VAC Full-Load
1.5A max @220VAC Full-Load
See Inrush Current section in datasheet
47–63Hz
>0.9 @ 60–100% Load

PROTECTION

Short Circuit

Over Voltage

Auto recovery after fault removal

ENVIRONMENT

Operation Temperature
Operation Humidity
Storage
Temperature Coefficient
Vibration Resistance

−40°C ~ +90°C
20 ~ 90%
−40°C ~ +85°C, 5 ~100%RH
±0.03% / °C (-45 ~ 50°C)
10 – 500HZ, 2G 10Min / period, X, Y, Z line
per 60 mins

SAFETY & EMC

Standard

Withstand Voltage
Insulating Strength

EMC Emission

EMC Immunity

UL8750, UL1012, IEC61347-1, IEC61347-2-13, IEC62384
I/P-O / P:3.75KVAC
I/P-O / P:400M Q / 500 VDC / 25°C / 70%RH
IEC55015, IEC61000-3-2, IEC61000-3-3, FCC Part 15 Class B
IEC61000-4-2, 3, 4, 5, 6, 8, 11, IEC61547

Manual

This field is hidden when viewing the form
This field is hidden when viewing the form