HX Lighting Products

For underground mining, tunnelling and tunnel construction.

HX 300w-48vDC-Single Output | Power Supply

Suitable for the HX 48v DC LED rope lights with single output. IP67 outdoor/hazardous environments.

Features

  •       The output voltage is constant
  •       Input voltage: 100-277VAC
  •       Using active built-in PFC technology
  •       Efficiency >90% PF >0.98
  •       Protection: SCP/OVP
  •       Aluminum case waterproof
  •       Easy to install
  •       Nature cooling
  •       CE/ROHS/SAA/TUV certs. CE/ROHS/SAA/TUV
  •       5 Years warranty

Applications

Industrial: Conveyors, marine & submarine lighting, rail car lighting, catwalks, storage room lighting, accessways, wash down areas, service bays lighting, Crane machine houses & walkways, electrical rooms and bulk handling processing facilities.

Mining: Underground mine lighting for declines, shafts, drifts, crosscuts, longwall prep areas, electrical substations, jumbo box lighting, pump houses, cuddy and underground workshop lighting, crib rooms, accessways and escapeway lighting.

Tunnelling: Tunnel construction lighting, tunnel emergency lighting, sewerage & water utility tunnels, underpasses, train and pedestrian tunnels.

Specification

MODEL CV HX 300W-48VDC

OUTPUT

Output Voltage
Voltage Precision
Output Current
Output Power
Line Regulation

48V

6.25A
300W
1%

INPUT

Input Voltage Range

AC Current (Typ)

Inrush Current (Typ)

Frequency Range
PFC (Typ)
Full-loading Efficiency

100 – 277V / AC(standard) 85VAC (min) 305V / AC (max)
3.26A @ 100VAC 2.964A @ 110VAC 1.417A @ 230VAC 1.251A @ 264VAC
COLD START 9A (twidth = 50μs measured @ 50% Ipeak) @ 230V
47 – 63Hz
>0.95 @ full load
90%

PROTECTION

Short Circuit

Over Voltage

Short circuit protection / Over voltage protection
< 305VAC

ENVIRONMENT

Operation Temperature
Operation Humidity
Storage
Temperature Coefficient
Vibration Resistance

-40~ + 60°C
20 ~ 90%
-40 ~ +85°C, 10 ~ 95%RH
±0.03% / °C (-45 ~ 50°C)
10 – 500HZ, 2G 10Min / period, X, Y, Z line
per 60 mins

SAFETY & EMC

Standard

Withstand Voltage
Insulating Strength

EMC Emission

EMC Immunity

Refer to EN 61347-1;EN 61347-2-13; EN 62493
I/P-O / P:3.75KVAC
I/P-O / P:400M Q / 500 VDC / 25°C / 70%RH
To Correspond EN55015, EN61000-3-2
(≥50% load)
To Correspond EN55015, EX61000-4-2, 3, 4, 5, 6, 8, 11, A Level of light industry standard (Surge 4KV)

Manual

This field is hidden when viewing the form
This field is hidden when viewing the form