HX Lighting Products

For underground mining, tunnelling and tunnel construction.

HX 1200w-48vDC-Single Output | Power Supply

Suitable for the HX 48v DC LED rope lights with single output. IP67 outdoor/hazardous environments.

Features

  •       Constant Voltage mode LED power supply
  •       Supply Voltage: 180-528Vac
  •       Great Surge Immunity 10kV
  •       Low Inrush Current
  •       100,000Hour Life @ Tc=75°C
  •       5 Year Warranty @ Tc<=75°C
  •       UL Class P, ENEC/CB/CCC SELV Output
  •       Safety according to UL8750, EN 61347-1, 61347-2-13, 62384

Applications

Industrial: Conveyors, marine & submarine lighting, rail car lighting, catwalks, storage room lighting, accessways, wash down areas, service bays lighting, Crane machine houses & walkways, electrical rooms and bulk handling processing facilities.

Mining: Underground mine lighting for declines, shafts, drifts, crosscuts, longwall prep areas, electrical substations, jumbo box lighting, pump houses, cuddy and underground workshop lighting, crib rooms, accessways and escapeway lighting.

Tunnelling: Tunnel construction lighting, tunnel emergency lighting, sewerage & water utility tunnels, underpasses, train and pedestrian tunnels.

Specification

MODEL CV HX 1200W-48VDC

OUTPUT

Output Voltage
Voltage Precision
Output Current
Output Power
Line Regulation

48VDC

25A
1200W
Vp-p: 5% Vo max
1.5s max

INPUT

Input Voltage Range

AC Current (Typ)

Inrush Current (Typ)

Frequency Range
PFC (Typ)\
Full-loading Efficiency

180–528VAC (380VAC for 2 hours)

6.5A @208VAC / 6.0A @220VAC / 4.5A @277VAC / 2.7A @480VAC

47–63Hz
>0.9 @ 60–100% Load

PROTECTION

Short Circuit

Over Voltage

Auto recovery. The output recovers when short is removed.
Turn off the output when Tc≧105±10°C;
Auto Recovery When Tc≦70±10°C

ENVIRONMENT

Operation Temperature
Operation Humidity
Storage

-40°C/40F~+90°C/194F;10%RH~100%RH
20 ~ 90%
-40°C/40F~+85°C/185F; 5%RH~100%RH

SAFETY & EMC

Standard

Withstand Voltage
Insulating Strength

EMC Emission

EMC Immunity

UL8750, UL1012, IEC61347-1, IEC61347-2-13, IEC62384
I/P-O / P:3.75KVAC
I/P-O / P:400M Q / 500 VDC / 25°C / 70%RH
To Correspond EN55015, EN61000-3-2
(≥50% load)
8kV Air / 4kV Contact

Manual

This field is hidden when viewing the form
This field is hidden when viewing the form